401B Technical Specifications
FREQUENCY | |
Frequency Range: |
1 MHz to 1024 MHz |
Span: |
0 to 1023 MHz |
Span Accuracy: |
±50 ppm |
Frequency Markers: |
3 |
Marker Resolution (Frequency): |
1% of span or 100 kHz |
Marker Resolution (Amplitude): |
0.1 dB |
Marker Readout Accuracy: |
1% of span ±50 ppm |
Resolution Bandwidth, 3dB: |
120 kHz, 1 MHz |
Video Bandwidth: |
30 kHz, 300 kHz |
Sweep Time: |
300ms, typical |
|
GENERAL | |
Display: |
Monochrome LCD |
Display Backlight (Optional): |
Electro-luminescent |
Operating Temperature Range: |
0ºC to 40ºC |
Storage Temperature: |
-10ºC to 50ºC |
Line Power: |
6VA |
Power (12-14 VDC): |
0.4A max |
Dimensions, mm: |
193H x 102W x 33D |
Dimensions, inches: |
7.6H x 4.0W x 1.3D |
Weight: |
1.2 lbs (0.55 kg) |
Safety and Electromagnetic Compatibility: |
CE Mark Compliance |
|
AMPLITUDE | |
Measurement Range: |
-25 dBm to -95 dBm |
Displayed Average Noise Level 100 kHz Resolution B/W, typical: |
-95 dBm, span<10MHz -90 dBm, span>10MHz |
Reference Level Accuracy: |
±1 dB at -30 dBm |
Maximum Safe Input Level: |
+23 dBm, 50 VDC |
Scale: |
1, 2, 5, 10, 20 dB/div |
Measurement Units: |
dBm, dBµV |
Intermods (3rds, -35dBm signals): |
-75 dBc, typical |
Harmonic Distortion (-35 dBm): |
-75 dBc, typical |
Amplitude Accuracy: |
±2.5 dB, -25 to -70 dBm |
Detection Modes: |
Normal, Quasi-Peak, and Peak Hold |
Input Connector: |
SMA (Female) |
|
OTHER FEATURES | |
Save/Recall, Setups: |
20 |
Save/Recall, Traces: |
20 |
RS-232 Interface Speed: |
9600, 57600 Baud |
RS-232 Interface Connector: |
DB-9 (Female) |
Stored EMC Specifications: |
FCC Part 15 A/B, CISPR 11 A/B, 22 A/B |
Data Download Modes: |
Screen display as bitmap or Excel compatible |
|
Active Components For The Model 401B Spectrum Analyzer
|
 |
 |
 |
P101A ACTIVE E-FIELD PROBE |
Frequency Range: |
30 MHZ - 1024 MHZ |
Sensitivity at 30 MHZ: |
57 dBµV/m, typical |
Output Connector: |
SMA Male |
Length: |
36 inches (91 cm) |
| |
|
|
|
 |
P201A ACTIVE H-FIELD PROBE |
Frequency Range: |
30 MHZ - 1024 MHZ |
Sensitivity at 1024 MHZ: |
57 dBµV/m, typical |
Sensitivity at 30 MHZ: |
87 dBµV/m, typical |
Output Connector: |
SMA Male |
Length: |
36 inches (91 cm) |
| |
|
|
|
 |
ANT01A ACTIVE H-FIELD PROBE |
Frequency Range: |
30 MHZ - 1024 MHZ |
Sensitivity at 30 MHZ: |
57 dBµV/m, typical |
Output Connector: |
SMA Male |
Length, including connector: |
3.2 inches (8.1 cm) |
Diameter: |
.375 inches (9.5 mm) |
| |
|
|
|
 |
PA01A PREAMPLIFIER |
Frequency Range: |
1 MHZ - 1024 MHZ |
Gain: |
26 dB, typical |
Input Connector: |
Type N, Male |
Output Connector: |
SMA Male |
Size, excluding connectors: |
2.25 x 1.4 x 1.2 inches (5.7 x 3.6 x 3.1 cm) |
| |
|
|
Note: DC Power for the above devices is supplied by the 401B. The active device must be connected directly to the 401B input connector. Active devices cannot be cascaded.
Model 401B Personal Spectrum Analyzer
|
|